LiYY (TP)

LiYY (TP)

Application

The high level of screening reduces substantially the effects of electrical disturbances. These cables are used for data & signal transmission.

Specifications

Standard : Based on VDE 0812
Nominal Voltage (Not for power application) : 0.14 mm² = 350 V; >/= 0.25 mm² = 500V
Insulation Resistance : Min. 20 GΩ x cm
Temperature Range : Flexing -5°C to +70°C. Fixed installation -30°C to +70°C
Minimum Bending Radius : Flexing 15 x cable ø. Fixed installation 6 x cable ø
Test Voltage : 0.14 mm² : 1200 V; > 0.14 mm² : 1500 V
Capacitance (approx. Value)
Up to 0.5 mm²
C/C = 120 nF/km. C/S = 160 nF/km
0.75 mm² to 1.5 mm²
C/C = 160 nF/km. C/S = 240 nF/km
Inductance : Approx. 0.65 mH/km

Cable Construction

Bare copper, fine wire conductors, to DIN/BS EN 60228 cl.5.
Conductor make-up for
0.14 mm² = 18 x 0.1 mm.
0.25 mm² = 14 x 0.15 mm.
0.34 mm² = 19 x 0.15 mm.
Special PVC core insulation TI2, to EN 50363-3.
Colour coded to DIN 47100, but without colour repetition, refer table 2.2.
Cores stranded in pair with optimal lay-length.
Cores stranded in layers with optimal lay-length.
Tinned copper braided screen, approx 85% coverage.
Special PVC outer sheath TM2, to EN 50363-4.1.
Sheath colour grey (RAL 7032).

Properties

Overall braid minimizes electrical interference.
Flame retardant to EN 60332-1-2.
Smaller dimension screened cables are suitable for use in computer systems, instrumentation technology office equipment, balance, etc.